Lithium batteries are widely used in our daily lives, but their use can lead to accidents such as explosions. Therefore, lithium battery testing is a necessary and crucial step in production. Li ion battery testing can also reveal performance issues. Through systematic performance testing, a battery’s electrochemical characteristics, reliability, and safety can be comprehensively assessed. This article will detail lithium battery testing items and corresponding test methods, providing an understanding of the standards for various battery parameters.
Lithium Ion Battery Testing: Capacity Test
Test purpose: Determine the actual discharge capacity of the battery to verify compliance with the rated capacity standard.
Test equipment: Charge and Discharge Tester, Constant Temperature Chamber (25°C ± 2°C).
Test procedure:
- Battery preconditioning: Allow the battery to rest at 25°C for 2 hours to ensure stable temperature.
- Standard charge: Charge at a constant current of 0.5C to the rated voltage, then switch to constant voltage charging until the current drops to 0.05C. Allow to rest for 1 hour.
- Standard discharge: Discharge at a constant current of 0.5C to the cutoff voltage (e.g., 3.0V for NMC batteries and 2.0V for LFP batteries). Record the total capacity during discharge.
- Repeat test: Perform three consecutive tests and take the average value as the final capacity (deviation must be ≤5%).
Note: New batteries should be tested after 3-5 charge and discharge cycles to avoid initial capacity deviation.
Lithium Battery Testing: DC Internal Resistance (DCIR) Test
Test purpose: Evaluate the battery’s internal resistance under DC conditions, reflecting its conductivity and polarization.
Test equipment: Internal resistance tester, charge-discharge tester.
Test steps:
- Battery conditioning: Test the internal resistance at full charge (100% SOC), half charge (50% SOC), and empty charge (20% SOC).
Full charge: Charge to full capacity according to the standard and allow to rest for 30 minutes.
Half charge: Discharge at 0.5C to 50% SOC (calculate the discharge amount based on the rated capacity) after full charge and allow to rest for 30 minutes.
Empty charge: Discharge at 0.5C to 20% SOC after full charge and allow to rest for 30 minutes.
- Pulse test: Pulse discharge at 1C for 10 seconds in each state. Record the pre-discharge voltage (U1) and the voltage after 10 seconds of discharge (U2).
- Calculate internal resistance: DCIR = (U1 U2) / Discharge Current (unit: mΩ).
Note: The pulse time must be strictly controlled (usually 5-10 seconds) to avoid a sharp rise in battery temperature that may affect the results.
Li Ion Battery Testing: AC Internal Resistance (ACIR) Test
Test purpose: To measure the internal resistance of lithium batteries using an AC signal, reflecting the electrode interface reaction and electrolyte ion conductivity.
Test equipment: Electrochemical workstation (or AC impedance meter).
Test steps:
- Battery condition: Typically tested at full charge or 50% SOC, and allowed to rest for 30 minutes.
- Test parameters: Frequency range 10mHz-10kHz, AC signal amplitude 5-10mV (avoid overpolarization).
- Impedance spectroscopy: Connect the battery to the electrochemical workstation, apply an AC signal, and record the impedance spectrum (Nyquist plot). The impedance value in the high-frequency region (e.g., 1kHz) is read as the ACIR.
Note: Before testing a lithium battery, ensure that the battery is intact to avoid signal interference. High-frequency impedance primarily reflects ohmic internal resistance, while low-frequency impedance reflects electrochemical polarization.
High Rate Charge and Discharge: Double Charge, Double Discharge Test
Test purpose: Verify the battery’s charge and discharge capabilities and stability at high rates.
Test equipment: High-rate charge and discharge tester, temperature recorder, explosion-proof box.
Test steps:
- Discharge test:
After fully charging, let the battery rest for 1 hour. At 25°C, discharge the battery at constant currents of 1C, 3C, 5C, and 10C (rate determined by product design) to the cutoff voltage.
Record the discharge capacity, voltage curve, and maximum battery surface temperature (must be ≤ 60°C). Calculate the high-rate capacity retention (high-rate capacity / 0.5C capacity × 100%).
- Charge test:
After discharging the battery, let it rest for 1 hour. Charge the battery at constant currents of 1C, 2C, and 3C to the rated voltage, then switch to constant voltage charging to a current of 0.05C.
Record the charging time, voltage change, and temperature, and observe for abnormalities such as bulging or leakage.
Note: High-rate testing must be performed in an explosion-proof box. Monitor the temperature in real time. If the temperature exceeds 60°C or the voltage is abnormal, stop immediately.
Lithium Battery Testing: High and Low Temperature Discharge Test
Test purpose: Evaluate the battery’s discharge performance at extreme temperatures, suitable for use in vehicles and outdoor environments.
Test equipment: High and low temperature constant temperature chamber, charge and discharge tester.
Test steps:
- High-temperature discharge (e.g., 45°C, 60°C):
After fully charging the battery, place it in a constant temperature chamber at a set temperature and let it rest for 4 hours (ensure the internal battery temperature is consistent with the ambient temperature).
Discharge the battery at a current of 0.5C to the cutoff voltage. Record the discharge capacity, voltage curve, and temperature change to calculate the high-temperature capacity retention.
- Low-temperature discharge (e.g., -10°C, -20°C):
The test procedure is the same as for high-temperature discharge, but the temperature is set to low and the resting time is extended to 6 hours (heat conduction is slow at low temperatures).
Record the discharge capacity (focusing on the degree of capacity decay at low temperatures) and any voltage drop.
Note: After low-temperature discharge, the battery voltage may rebound; the capacity at the end of discharge should be used as the reference. After testing lithium batteries, return the battery to room temperature before performing subsequent operations.
Lithium Ion Battery Testing: Storage Performance Test
Test purpose: Evaluate the battery’s capacity retention and self-discharge rate after long-term storage.
Test equipment: Constant Temperature Chamber, Charge-Discharge Tester.
Test procedure:
- Storage at room temperature (25°C ± 2°C):
The battery is charged at 0.5C to 50% SOC (recommended storage condition). After standing for 1 hour, it is placed in a constant temperature chamber and the initial capacity (C0) is recorded.
Store the battery for 7, 30, 90, and 180 days, remove it, stand it for 2 hours, and discharge it at 0.5C to the cutoff voltage. The post-storage capacity (C1) is recorded.
Calculate the capacity retention (C1/C0 × 100%) and self-discharge rate ((C0 – C1) / C0 / number of days stored × 100%).
- High-temperature storage (e.g., 40°C, 60°C):
The process is the same as for normal temperature storage, but the storage temperature is higher and the storage time is shorter (e.g., 30 days at 60°C). Pay close attention to any signs of bulging or leakage. Perform a capacity recovery test after storage (charge followed by discharge to see if the capacity recovers).
Note: During storage, regularly inspect the battery’s appearance to avoid short circuits or damage. High-temperature storage may irreversibly reduce the battery’s lifespan and requires individual labeling.
Lithium Battery Testing: Cycle Life Test
Test purpose: To determine the capacity decay pattern of a battery after multiple charge and discharge cycles and to evaluate the service lithium battery life.
Test equipment: Charge and discharge tester, constant temperature chamber (25°C or a specific temperature).
Test steps:
- Initial capacity test:
Determine the initial capacity (C0) according to the “Capacity Test” method.
- Cycle test:
Ambient temperature cycle: At 25°C, charge at 1C (constant current and constant voltage) to full charge, let stand for 30 minutes, then discharge at 1C to the cutoff voltage, let stand for 30 minutes. This completes one cycle.
Accelerated cycle: This can be performed at 45°C or a high rate of 2C to shorten the test cycle.
- Capacity monitoring:
After every 50 cycles, measure the capacity (Cn) according to standard methods until Cn ≤ 80% × C0. Record the number of cycles (i.e., the cycle life).
Note: During the cycling process, record the voltage curve for each charge and discharge to observe any abnormalities (such as a drop in the voltage plateau or an increase in internal resistance).
Lithium Battery Testing: Safety Performance Test
Test purpose: Verify battery safety under abuse conditions to avoid risks such as fire and explosion.
Test equipment: Explosion-proof chamber, short-circuit tester, extruder, puncture device, high-temperature chamber, drop table.
- Overcharge test
Steps: After fully charging the battery, continue charging at 1C until the voltage reaches 1.5 times the rated voltage (e.g., 5V for ternary lithium batteries) or for 2 hours. Observe for fire, explosion, or leakage.
Criteria: Acceptable if no fire or explosion occurs.
- Overdischarge test
Steps: After discharging the battery, continue discharging at 0.5C to 0V. Let it rest for 2 hours and observe for bulging. Then perform standard charge and discharge to check for recovery of performance.
- Short-circuit test
Steps: Short-circuit the cathode and anode terminals of the battery with a wire with a resistance of ≤50mΩ. Record the temperature change within 5 minutes after the short circuit and any fire or explosion.
- Compression test
Steps: Secure the battery and compress it with a 30mm diameter steel rod at a speed of 10kN/min (perpendicular to the electrode plane) until the battery casing ruptures or the pressure reaches 100kN. Observe for fire within one hour.
- Puncture test
Steps: Use a 3mm diameter steel needle (tip angle 30°) to pierce the center of the battery (through the positive and negative electrodes) at a speed of 10mm/s. Remove the needle and observe for fire or explosion within one hour.
- Drop test
Steps: Drop the battery from a height of 1m onto a concrete floor (one drop on each of the six sides). After the drop, allow the battery to rest for two hours. Inspect the battery for appearance and leakage, and then test the battery capacity to ensure normal operation.
- High-temperature shock test
Steps: Place the battery in a high-temperature chamber and heat it to 130°C ± 2°C at a rate of 5°C/min. Maintain the temperature for 30 minutes and observe for signs of fire or explosion.
Note: All safety tests must be conducted in an explosion-proof chamber, and operators must wear protective equipment. Lithium batteries must be stored separately after testing to avoid secondary risks.
Conclusion
Lithium battery testing must cover electrochemical performance (capacity, internal resistance, rate capability), environmental adaptability (high and low temperature, storage), lifespan (cycling), and safety. Testing standards for different application scenarios (such as consumer electronics and power batteries) need to be tailored to meet specific needs.
Systematic testing ensures the stability and safety of lithium batteries during use, providing data support for product design and application. Furthermore, rigorous performance testing ensures battery quality and safety, ensuring safe device use.