Battery system electrical performance parameters
| Parameter | Specification | Condition/Note |
|---|---|---|
| Connection | 1P24S | |
| Nominal voltage | 76.8V | 3.2V*24S |
| Nominal capacity | 40Ah | At a 0.33C discharge current (25±2°C) |
| Rated energy (Wh) | 3072 | |
| Max operating voltage | 87.6V | 3.65V*24 |
| Minimum operating voltage | 60V | 2.5V*24 |
| Charge Method (software) | CAN protocol charging | |
| Temperature range (Charging) | 0~55 °C | |
| Temperature range (Discharging) | -20~60 °C | |
| Standard charge current | 20A | |
| Standard discharge current | 40A | |
| Max discharge current (continuous) | 80A | |
| Max sustainable discharge current | 100A/30S | 20~55℃, ≥50%SOC |
| AC impedance | ≤60m Ω | SOC=50% At 25℃ 1KHz |
| Static pressure difference during system shipment | ≤30mV | 50% to 60%SOC (storage mode) |
| Self-discharge | ≤3.5%/month | Fresh cell after 3 months, 40%SOC, 25±2 °C storage |
| Working ambient humidity | 65%±20% |